Show simple item record

dc.contributor.advisorNichols, Michael G.en_US
dc.contributor.authorHansen, Mariaen_US
dc.date.accessioned2009-09-03T16:31:03Z
dc.date.available2009-09-03T16:31:03Z
dc.date.issued2009-06-11en_US
dc.identifier.otherThesis - Hansen.pdf
dc.identifier.urihttp://hdl.handle.net/10504/118
dc.description.abstractLipophilic-fluorescent dyes are used as probes to study the neural pathways that wire the brain. Since these dyes are able to define neuroanatomic connections through all stages of normal and mutant development, they are currently the most comprehensive method for neurotracing. In order to efficiently trace such circuitry, it is necessary to use a diffusion-matched set of spectrally distinct dyes. The fluorescent dye molecule is composed of a fluorescent head group and two hydrocarbon chains. This thesis addresses how the molecular structure of a lipophilic-fluorescent dye affects the diffusion rate by considering both the configuration of the fluorescent head group and the hydrocarbon chain length. Since the diffusion rate may also depend on the concentration of a dye, this parameter was investigated as well. Three hypotheses were addressed by measuring these parameter independently. Each dye was measured and compared using the Diffusion Distance vs. Incubation Period technique. FRAP was also used as anotherapproach for measuring the dyes. Hypothesis I: The structure of the fluorescent head group affects the diffusion coefficient. The investigation of this hypothesis demonstrated that the fluorescent head group can affect the diffusion rate. Hypothesis II: The diffusion parameters are dependent on the applied concentration. From this investigation, the results did not support the hypothesis. Hypothesis III: The diffusion coefficient is dependent on the lengths of the hydrocarbon chains. The results from these measurements demonstrate faster diffusion rates with increasing chain length.en_US
dc.language.isoen_USen_US
dc.publisherCreighton Universityen_US
dc.subject.lcshDyes and dyeing--Chemistry.en_US
dc.subject.lcshDiffusionen_US
dc.subject.lcshNerves, Peripheralen_US
dc.titleMeasuring and Comparing the Diffusion Rate of Fluorescent-Lipophilic-Neurotracing Probes in Murine-Peripheral-Nerve Preparationsen_US
dc.typeThesis
dc.rights.holderMaria Rose Hansenen_US
dc.publisher.locationOmaha, Nebraskaen_US
dc.contributor.cuauthorHansen, Mariaen_US
dc.embargo.terms2010-06-11
dc.degree.levelMS (Master of Science)en_US
dc.degree.disciplinePhysics (graduate program)en_US
dc.degree.nameM.S. in Physicsen_US
dc.degree.grantorGraduate Schoolen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record